# IEEE 2030.5: the Smart Energy Profile for DER and customer devices

IEEE 2030.5 is the IEEE application protocol, also known as Smart Energy Profile 2.0, that lets utilities exchange schedules, controls and data with inverters, storage, EV chargers and other energy devices over IP networks.

[Discuss your project](https://quantlix.com/en/contact/) [Read the key points](https://quantlix.com/en/standards/ieee-2030-5/#standard-overview)

## At a glance

**Full name**

IEEE Standard for Smart Energy Profile Application Protocol

**Published by**

IEEE Standards Association, sponsored by the IEEE Communications Society (SEP2 working group)

**Type**

Application protocol standard

**Current version**

IEEE 2030.5-2023, approved 6 December 2023 and published 11 December 2024; supersedes 2030.5-2018, with Cor 1-2024 rolled in

**Applies to**

Utilities, DER aggregators and makers of inverters, storage, EV chargers and energy management systems

**Last reviewed**

November 16, 2026 (2026-11-16)

## In plain terms

### Key points

- It is a RESTful protocol over HTTP and TCP/IP, with security features that include TLS and device certificates.
- Its scope covers distributed generation, demand response, load control, time-of-day pricing and electric vehicles.
- California's Rule 21 names it the default application-level protocol for smart inverter communications.
- IEEE 1547-2018 lists it as one of three protocols a DER can support at its local communication interface.
- The current edition is IEEE 2030.5-2023, published in December 2024, which replaced the 2018 edition.

### What is IEEE 2030.5?

IEEE 2030.5 is **the Smart Energy Profile application protocol**, an IEEE standard that lets a utility or aggregator talk to energy devices at the edge of the grid. It began life as Smart Energy Profile 2.0, and the IEEE working group still carries the SEP2 name.

It exists because rooftop solar, batteries and EV chargers now shape how a distribution grid behaves. Utilities need a common way to send schedules, limits and settings to these devices and to read back what they are doing, without a custom integration for every brand. IEEE 2030.5 gives them that shared language, built on familiar web technology.

### What IEEE 2030.5 covers

- **Distributed energy resources.** Controls and schedules for inverters and storage, such as active power limits, power factor and volt-var settings, plus status and monitoring.
- **Demand response and load control.** Events that ask devices to reduce or shift load for a set period.
- **Pricing.** Time-of-day and other tariff information for devices that respond to price.
- **Metering.** Readings from meters and devices, so the utility can see what a site produces and consumes.
- **Electric vehicles.** Charging-related functions alongside the other energy devices on site.
- **Security.** Message exchange over TLS with device certificates, and rules for how devices are identified and registered.

### How it works

IEEE 2030.5 uses a **RESTful architecture over HTTP**, on the four-layer internet model. The utility side runs a server that publishes resources, such as DER programs and their controls, and each device or gateway acts as a client that reads them, follows the schedules and posts back responses and readings. Lower layers such as a particular radio are mostly out of scope, so the protocol runs over whatever IP network a site has. Its information model draws on IEC 61968 and [IEC 61850](https://quantlix.com/en/standards/iec-61850/), which helps when utility systems already use those models.

### Where it is used: Rule 21 and IEEE 1547

California made IEEE 2030.5 central to smart inverter communications. Under Rule 21, the California Public Utilities Commission (CPUC) has confirmed that IEEE 2030.5 is the default application-level protocol, with other protocols allowed by mutual agreement. Resolution E-5000 of July 2019 set out four ways to meet the communication requirement: directly to the inverter, through a site energy management system, through an aggregator or through another agreed path. Testing uses the Common Smart Inverter Profile (CSIP), an implementation guide that narrows the standard for this use. In August 2025 the CPUC opened proceeding R.25-08-004 to consider refinements to Rule 21, so check the current tariff before you design.

Nationally, IEEE 1547-2018 requires distributed energy resources to offer a local communication interface that supports at least one of IEEE 2030.5, IEEE 1815 ([DNP3](https://quantlix.com/en/standards/dnp3/)) or SunSpec Modbus. Which one a project needs depends on the utility and the state regulator. For customer-side demand response, many programs use [OpenADR](https://quantlix.com/en/standards/openadr/) instead or alongside.

### How it shows up in software projects

- **Certificates and identity.** Every device needs a certificate, and the software manages enrollment, renewal and revocation and maps device identifiers to customer sites.
- **Scheduling logic.** DER controls arrive as timed events with start times, durations and priorities, and clients must resolve overlaps and return to default settings when a control ends.
- **Scale.** A utility server may serve large fleets of devices, so polling intervals, subscriptions and caching need careful design.
- **Aggregator paths.** When an aggregator or site gateway speaks IEEE 2030.5 to the utility and another protocol to the devices, the translation and its timing are documented and tested.
- **Edition and profile records.** Each integration records the edition (2018 or 2023) and the profile, such as CSIP, that the counterpart supports.

### How we work with IEEE 2030.5

We design and build the software around IEEE 2030.5 links: utility-side services and dashboards that manage DER programs, gateway and aggregator software that translates to device protocols, and test setups that check scheduling and certificate handling before field rollout. Our [cloud architecture](https://quantlix.com/en/services/cloud-architecture/) work helps you plan for device fleets that keep growing.

Interconnection approval and inverter certification belong to the utility, the device maker and the test labs your tariff relies on. We help you prepare the evidence those reviews ask for. This work is part of our Utilities and Infrastructure practice under [Dr. Abdel-Hadi Hor](https://quantlix.com/en/about/leadership/abdel-hadi-hor/).

## Where it applies

Industries where this standard often shapes the work.

- ### [Energy & Utilities](https://quantlix.com/en/industries/energy-and-utilities/)

  Renewable energy, smart grids and energy storage systems

## Related standards

[All standards](https://quantlix.com/en/standards/)

- OpenADR

  ### [Automated demand response signals](https://quantlix.com/en/standards/openadr/)

  OpenADR is the Open Automated Demand Response standard from the OpenADR Alliance, used by utilities and aggregators to send demand response, price and grid signals to customer systems and receive reports back.
- DNP3

  ### [SCADA protocol for field devices](https://quantlix.com/en/standards/dnp3/)

  DNP3 is the Distributed Network Protocol, standardized as IEEE 1815, that SCADA masters use to poll and control RTUs and IEDs in electric, water and other utilities, with event reporting and time-stamped data.
- IEC 61850

  ### [Power utility automation and substations](https://quantlix.com/en/standards/iec-61850/)

  IEC 61850 is the international standard series for communication in power utility automation, defining device data models, the SCL configuration language and fast messaging for substations and other grid assets.
- Green Button

  ### [Customer energy usage data sharing](https://quantlix.com/en/standards/green-button/)

  Green Button is the North American initiative, built on the NAESB REQ.21 ESPI standard, that lets utility customers download their energy usage data or authorize apps to receive it directly.

## Services that support this work

The services we usually bring to projects that involve this standard.

[View all services](https://quantlix.com/en/services/)

### [IoT and edge computing](https://quantlix.com/en/services/iot-edge-computing/)

Connect machines, sensors and business software with assessed IoT and edge integrations. Define data meaning, connectivity, permitted actions and recovery.

### [Cloud architecture](https://quantlix.com/en/services/cloud-architecture/)

Quantlix designs cloud infrastructure around workload requirements, security boundaries, operational visibility and cost, with an explicit path for deployment and recovery.

### [Enterprise applications](https://quantlix.com/en/services/enterprise-applications/)

Quantlix designs and builds enterprise applications for internal workflows, business rules and system integration, with clear access controls and maintainable architecture.

## Questions, answered

What teams usually ask us about this standard.

**Is IEEE 2030.5 required in California?**

California's Rule 21 makes IEEE 2030.5 the default application-level protocol for smart inverter communications, and the CPUC allows other protocols by mutual agreement. Resolution E-5000 of July 2019 also confirmed that the requirement can be met through an energy management system or an aggregator rather than at every inverter.

**What is the latest version of IEEE 2030.5?**

IEEE 2030.5-2023, approved by the IEEE SA Standards Board on 6 December 2023 and published on 11 December 2024. It supersedes the 2018 edition, and corrigendum Cor 1-2024 has been rolled into the base standard.

**What is CSIP?**

The Common Smart Inverter Profile (CSIP) is an implementation guide that narrows IEEE 2030.5 for smart inverters under California Rule 21. SunSpec published the CSIP conformance test procedures in May 2018, and Rule 21 testing refers to the latest CSIP.

**How is IEEE 2030.5 different from OpenADR?**

Both can carry demand response and price signals. IEEE 2030.5 also defines detailed DER controls, settings and monitoring for inverters and storage, while OpenADR centers on demand response, pricing and similar signals sent from a utility or aggregator server to customer systems.

**How does IEEE 2030.5 relate to IEEE 1547?**

IEEE 1547-2018 sets interconnection and interoperability requirements for distributed energy resources, including a local communication interface. IEEE 2030.5, IEEE 1815 (DNP3) and SunSpec Modbus are the three protocols it accepts at that interface.

## Official sources

Read the official text before relying on any detail. What applies to you depends on your role, your location and the version in force.

- [IEEE 2030.5-2023 on IEEE SA](https://standards.ieee.org/ieee/2030.5/11216/)
- [Rule 21 interconnection (CPUC)](https://www.cpuc.ca.gov/industries-and-topics/electrical-energy/infrastructure/rule-21-interconnection)
- [CPUC Resolution E-5000 on smart inverter communications (2019)](https://docs.cpuc.ca.gov/PublishedDocs/Published/G000/M309/K713/309713654.PDF)
- [IEEE 1547-2018 on IEEE SA](https://standards.ieee.org/ieee/1547/5915/)