title: "IEC 62443 explained: industrial cyber security | Quantlix"
description: "IEC 62443 is the international series for securing industrial automation and control systems. Learn its parts, zones and conduits, security levels and certification."
canonical: "https://quantlix.com/en/standards/iec-62443/"
last-updated: 2026-11-16
---

Source: https://quantlix.com/en/standards/iec-62443/
Language: en
Description: IEC 62443 is the international series for securing industrial automation and control systems. Learn its parts, zones and conduits, security levels and certification.

**IEC 62443** [Security and resilience](https://quantlix.com/en/standards/#security)

# IEC 62443: security for industrial automation and control systems

IEC 62443 is the international series of standards for securing industrial automation and control systems, with requirements for asset owners, service providers, system integrators and product suppliers.

[Discuss your project](https://quantlix.com/en/contact/) [Read the key points](https://quantlix.com/en/standards/iec-62443/#standard-overview)

## At a glance

**Full name**

Security for industrial automation and control systems (IEC 62443 series, also known as ISA/IEC 62443)

**Published by**

IEC Technical Committee 65, developed jointly with the ISA99 committee of the International Society of Automation (ISA)

**Type**

International standard series (some parts are technical specifications or publicly available specifications)

**Current version**

Revised part by part; for example 2-1 Ed. 2.0 (2024), 2-4 Ed. 2.0 (2023), 3-3 Ed. 1.0 (2013), 4-1 Ed. 1.0 (2018) and 4-2 Ed. 1.0 (2019)

**Applies to**

Asset owners, integrators, service providers and product suppliers of industrial automation and control systems (IACS) in any sector

**Last reviewed**

November 16, 2026 (2026-11-16)

## In plain terms

### Key points

- The series is organized in four groups: general concepts, policies and procedures, system requirements and component requirements.
- Part 3-2 divides a system into zones and conduits and gives each one a target security level.
- Seven foundational requirements, from identification and authentication to resource availability, run through the system and component parts.
- Certification is offered by separate schemes such as ISASecure and the IECEE, not by the standard itself.

### What is IEC 62443?

IEC 62443 is **the international series of standards for the security of industrial automation and control systems (IACS)**. It is developed jointly by IEC Technical Committee 65 and the ISA99 committee of the International Society of Automation, which is why you also see it written as ISA/IEC 62443.

Factories, pipelines, water plants and power systems depend on controllers and software that were often designed for availability first. The series gives everyone involved a shared way to manage cyber risk: the asset owner who runs the system, the integrator who builds it, the service provider who maintains it and the supplier who makes each product.

### What IEC 62443 covers

- **General.** Part 1-1, a 2009 technical specification, sets the terms, concepts and models, including seven foundational requirements such as identification and authentication, use control, data confidentiality and resource availability.
- **Policies and procedures.** Part 2-1 (Edition 2.0, 2024) sets security program requirements for asset owners, and Part 2-4 (Edition 2.0, 2023) does the same for service providers such as integrators and maintenance contractors.
- **System.** Part 3-2 (2020) covers risk assessment and zone design, and Part 3-3 (2013) lists system security requirements and security levels.
- **Component.** Part 4-1 (2018) defines a secure product development lifecycle, and Part 4-2 (2019) sets technical requirements for embedded devices, network devices, host devices and software applications.
- **Newer topics.** Publicly available specifications from 2025 cover an IACS security protection scheme (PAS 62443-2-2) and applying the series to the industrial internet of things (PAS 62443-1-6).

### Zones, conduits and security levels

The core design idea is to **divide a system into zones and conduits**. A zone groups assets with similar security needs, such as a control network or a safety system, and a conduit is the communication path between zones. Part 3-2 explains how to assess the risk of each zone and conduit and assign a target security level to each.

Security levels run from SL 1, protection against casual or accidental misuse, to SL 4, protection against sophisticated attackers with extensive resources and strong motivation. Systems and components then state the level they can achieve under Parts 3-3 and 4-2, and the gap between target and capability shows where more protection is needed.

### Certification

Certification sits outside the standard. ISASecure, the conformance assessment arm of ISA, certifies development lifecycles to Part 4-1, components to Part 4-2 and systems to Part 3-3. The IECEE, the IEC system for conformity assessment of electrotechnical equipment, runs its own scheme and issues certificates of conformity for parts including 2-4, 3-3, 4-1 and 4-2.

### How it shows up in software projects

- **Zone and conduit records.** Each deployment documents which zone every component sits in and which conduits it uses, agreed with the asset owner.
- **Secure development evidence.** Threat models, code reviews, dependency tracking and security tests are recorded so they map to Part 4-1 practices.
- **Component features.** Authentication, role-based authorization, audit logs and secure updates are designed against the Part 4-2 requirements for the target level.
- **Patch and vulnerability handling.** Each release follows a documented process for security updates and disclosure, which integrators and asset owners expect from suppliers.
- **Gap records.** Where a requirement is not met, the gap and its compensating control are written down so the asset owner can decide.

### How we work with IEC 62443

We help manufacturers, energy companies and their suppliers design and build industrial software with these requirements in view: architectures that respect zones and conduits at edge and cloud connections, development practices that produce Part 4-1 evidence, and component features mapped to Part 4-2. See our [IoT and edge computing](https://quantlix.com/en/services/iot-edge-computing/) service and how this applies in [manufacturing](https://quantlix.com/en/industries/manufacturing/) and [oil and gas](https://quantlix.com/en/industries/oil-and-gas/).

We never state a security level or certificate for software we build. A target level belongs to a specific system in a specific deployment, and certification comes from a qualified body such as ISASecure or an IECEE certification body. For power system protocols, see [IEC 62351](https://quantlix.com/en/standards/iec-62351/), and for pipelines, [API 1164](https://quantlix.com/en/standards/api-1164/).

## Where it applies

Industries where this standard often shapes the work.

- ### [Manufacturing](https://quantlix.com/en/industries/manufacturing/)

  Connected factories, quality inspection and production planning
- ### [Oil & Gas](https://quantlix.com/en/industries/oil-and-gas/)

  Asset monitoring, field data and maintenance planning
- ### [Energy & Utilities](https://quantlix.com/en/industries/energy-and-utilities/)

  Renewable energy, smart grids and energy storage systems

## Related standards

[All standards](https://quantlix.com/en/standards/)

- IEC 62351

  ### [Security for power system protocols](https://quantlix.com/en/standards/iec-62351/)

  IEC 62351 is the IEC series that adds authentication, encryption, access control and key management to the communication protocols that run power systems, such as IEC 61850, IEC 60870-5 and DNP3.
- NERC CIP

  ### [Cyber security for the bulk power system](https://quantlix.com/en/standards/nerc-cip/)

  NERC CIP is the family of mandatory reliability standards that protect the cyber systems and critical facilities of the North American bulk power system, from system categorization to supply chain risk.
- API 1164

  ### [Pipeline control system cybersecurity](https://quantlix.com/en/standards/api-1164/)

  API 1164 is the American Petroleum Institute standard for managing cyber risk in pipeline control systems, with requirements and guidance for protecting and isolating industrial automation and control environments.
- ISO/IEC 27001

  ### [Information security management systems](https://quantlix.com/en/standards/iso-iec-27001/)

  ISO/IEC 27001 is the international standard for an information security management system (ISMS): the policies, risk process and controls an organization uses to protect information and keep improving.

## Services that support this work

The services we usually bring to projects that involve this standard.

[View all services](https://quantlix.com/en/services/)

### [IoT and edge computing](https://quantlix.com/en/services/iot-edge-computing/)

Connect machines, sensors and business software with assessed IoT and edge integrations. Define data meaning, connectivity, permitted actions and recovery.

### [Technology assessment](https://quantlix.com/en/services/technology-assessment/)

Assess operational workflows, data, integrations and AI readiness. Quantlix helps define a bounded Proving Ground and evidence for the next investment decision.

### [DevOps engineering](https://quantlix.com/en/services/devops-engineering/)

Quantlix develops delivery pipelines, infrastructure automation and observability so teams can release software through repeatable, reviewable operational processes.

## Questions, answered

What teams usually ask us about this standard.

**Is IEC 62443 mandatory?**

Not in itself. It is a voluntary international series, but asset owners often write specific parts into specifications and supplier contracts, which makes them binding for that project.

**Which part of IEC 62443 applies to my product?**

Product suppliers usually start with Part 4-1 for the secure development process and Part 4-2 for component requirements. Integrators and service providers look at Parts 2-4 and 3-3, and asset owners at Parts 2-1 and 3-2.

**Is ISA/IEC 62443 the same as IEC 62443?**

Yes, the names refer to the same series. The ISA99 committee and the IEC develop the documents jointly, so you will see both names, and ISA also publishes the parts in the United States.

**What are IEC 62443 security levels?**

Security levels SL 1 to SL 4 describe protection against increasingly capable attackers, from casual or accidental misuse up to sophisticated attacks with extensive resources. A zone gets a target level, and systems and components state a capability level to compare against it.

**Can a product be certified to IEC 62443?**

Yes, through separate conformity assessment schemes. ISASecure certifies development lifecycles to Part 4-1, components to Part 4-2 and systems to Part 3-3, and the IECEE issues certificates of conformity for parts including 2-4, 3-3, 4-1 and 4-2. Each certificate states its own scope, such as a product version.

## Official sources

Read the official text before relying on any detail. What applies to you depends on your role, your location and the version in force.

- [IEC 62443 overview (IEC Systems Committee Smart Energy)](https://syc-se.iec.ch/deliveries/cybersecurity-guidelines/security-standards-and-best-practices/iec-62443/)
- [IEC 62443-3-2:2020 (zones, conduits and risk assessment)](https://webstore.iec.ch/en/publication/30727)
- [IEC 62443-4-2:2019 (component requirements)](https://webstore.iec.ch/en/publication/34421)
- [ISASecure certification programs](https://isasecure.org/certification)

These guides explain each standard in plain terms. They are not legal advice, and they do not state that any product or organization conforms to a standard.

## Planning software around this standard?

Tell us which systems are involved and what you need to show. We will help you build the requirements in from the start.

[Discuss your project](https://quantlix.com/en/contact/)