# IEC 61970-301: the Common Information Model base for power systems

IEC 61970-301 is the international standard that defines the base of the Common Information Model (CIM), a shared description of power system equipment, connectivity and measurements used across grid software.

[Discuss your project](https://quantlix.com/en/contact/) [Read the key points](https://quantlix.com/en/standards/iec-61970-301/#standard-overview)

## At a glance

**Full name**

Energy management system application program interface (EMS-API), Part 301: Common information model (CIM) base

**Published by**

International Electrotechnical Commission (IEC), Technical Committee 57

**Type**

International standard

**Current version**

Edition 7.0, published 26 June 2020, with Amendment 1 of 22 February 2022; sold consolidated as Edition 7.1

**Applies to**

Utilities, system operators and vendors whose control center, network analysis and planning systems exchange power system models

**Last reviewed**

November 16, 2026 (2026-11-16)

## In plain terms

### Key points

- It defines the core CIM classes for equipment, connectivity, measurements, generation and load that the other CIM parts build on.
- Edition 7.0 reflects CIM model version IEC61970CIM17v38 and added feeder, ICCP configuration and HVDC content.
- Profiles such as IEC 61970-452 select the classes an exchange needs, and IEC 61970-552 defines the CIMXML file format.
- The stability date is 2026, so confirm the edition with IEC before you write it into a contract.

### What is IEC 61970-301?

IEC 61970-301 is **the base of the Common Information Model (CIM)**, the shared vocabulary that power system software uses to describe the grid. Published by the International Electrotechnical Commission, it defines classes for the equipment in a network, how that equipment connects and the measurements taken from it.

It exists because energy management systems, network analysis tools and planning applications come from many vendors, each with its own internal model. When they agree on one abstract description of a breaker, a line or a transformer, a network model can move between them without being rebuilt by hand. The standard also models SCADA as far as power system simulation and communication between control centers require.

### What IEC 61970-301 covers

- **Identity and containment.** Every object has a persistent identity and a place in a hierarchy of regions, substations, voltage levels and bays.
- **Conducting equipment.** Lines, cables, transformers, breakers, switches and busbars, with the electrical parameters engineers need for calculations.
- **Connectivity and topology.** Terminals and connectivity nodes describe how equipment is wired together, so software can work out the electrical topology from switch positions.
- **Measurements and control.** Analog and discrete measurements, where they are taken and the control points linked to SCADA.
- **Generation, load and limits.** Generating units, load models and operational limits used by power flow, state estimation and contingency analysis.
- **Additions in Edition 7.** Feeder modeling, configuration of ICCP links between control centers, phase-shifting transformer examples and HVDC use cases.

### How it fits with profiles and exchange formats

The base model is deliberately broad, so no single exchange uses all of it. **A profile selects the classes, attributes and associations an exchange actually needs.** IEC 61970-452 (Edition 4.0, 2021) defines the static transmission network model profiles for state estimation and power flow, and IEC 61970-456 covers solved power system states. CGMES, published as IEC 61970-600-1 and 600-2 in 2021, packages profiles for exchanging common grid models between operators.

The file format is a separate layer. IEC 61970-552 (Edition 2.0, 2016) defines CIMXML, an XML format built on the CIM RDF schema. Profiles are also tied to a model release: the 2021 edition of IEC 61970-452, for example, is based on CIM UML version IEC61970CIM17v40. For distribution, [IEC 61968-11](https://quantlix.com/en/standards/iec-61968-11/) extends the same base with assets, customers and work, so transmission and distribution systems share one family of definitions.

### How it shows up in software projects

- **Model version pinning.** Each interface records the CIM edition, the UML model version and the profile it follows, because profiles built on different model releases are not interchangeable.
- **Identity management.** CIM objects carry persistent identifiers, so source system keys are mapped once and stay stable through model updates.
- **Topology processing.** Software that reads a CIM network rebuilds connectivity from terminals and nodes and applies switch states before running any analysis.
- **Validation before import.** Files are checked against the profile’s rules, such as required attributes and valid associations, so a faulty export is rejected before it reaches an operational system.
- **Extensions with discipline.** Local extensions live in their own namespace and are documented, so a later CIM release can be adopted without untangling them.

### How we work with IEC 61970-301

We design and build integrations around the CIM: mapping control center, GIS and planning data to CIM classes, producing and validating CIMXML exchanges for an agreed profile, and keeping a clear record of which model version each interface uses. Our Utilities and Infrastructure practice is led by [Dr. Abdel-Hadi Hor](https://quantlix.com/en/about/leadership/abdel-hadi-hor/), whose career spans utility GIS, asset, outage and distribution management systems.

A CIM-based design gives you a network model that outlives any single vendor. Whether two tools interoperate for a given profile is shown by testing them together, and we plan that testing into the project from the start. Read more about our work in [energy and utilities](https://quantlix.com/en/industries/energy-and-utilities/) or [talk to us](https://quantlix.com/en/contact/) about your model exchange.

## Where it applies

Industries where this standard often shapes the work.

- ### [Energy & Utilities](https://quantlix.com/en/industries/energy-and-utilities/)

  Renewable energy, smart grids and energy storage systems

## Related standards

[All standards](https://quantlix.com/en/standards/)

- IEC 61968-11

  ### [CIM extensions for distribution](https://quantlix.com/en/standards/iec-61968-11/)

  IEC 61968-11 is the international standard that extends the Common Information Model (CIM) to electricity distribution, so GIS, asset, outage and metering systems can describe the same network in the same way.
- IEC 61850

  ### [Power utility automation and substations](https://quantlix.com/en/standards/iec-61850/)

  IEC 61850 is the international standard series for communication in power utility automation, defining device data models, the SCL configuration language and fast messaging for substations and other grid assets.
- IEC 60870-5-104

  ### [Telecontrol over TCP/IP networks](https://quantlix.com/en/standards/iec-60870-5-104/)

  IEC 60870-5-104 is the international telecontrol standard that carries IEC 60870-5-101 messages over TCP/IP, so control centers can monitor and control substations and other remote sites over IP networks.

## Services that support this work

The services we usually bring to projects that involve this standard.

[View all services](https://quantlix.com/en/services/)

### [Enterprise applications](https://quantlix.com/en/services/enterprise-applications/)

Quantlix designs and builds enterprise applications for internal workflows, business rules and system integration, with clear access controls and maintainable architecture.

### [Data analytics](https://quantlix.com/en/services/data-analytics/)

Quantlix builds analytics pipelines and business intelligence tools that turn operational data into defined metrics, useful reports and decision support.

### [Legacy modernization](https://quantlix.com/en/services/legacy-modernization/)

Quantlix modernizes existing systems through targeted changes, integration and staged migration, preserving essential business behavior while addressing technical constraints.

## Questions, answered

What teams usually ask us about this standard.

**What is the latest edition of IEC 61970-301?**

Edition 7.0, published on 26 June 2020 and amended on 22 February 2022. IEC sells the two together as consolidated Edition 7.1. No later edition was listed on the IEC webstore when we checked in November 2026, and the stability date is 2026.

**What is the difference between IEC 61970-301 and IEC 61968-11?**

IEC 61970-301 is the base model for power system networks, used widely in transmission and control center software. IEC 61968-11 extends that base with the assets, customers, metering and work that distribution utilities need.

**Is the CIM the same as CGMES?**

No. CGMES, the Common Grid Model Exchange Standard, is a set of exchange profiles built on CIM classes and published as IEC 61970-600-1 and 600-2 in 2021. It fixes which parts of the model are exchanged and how they are validated.

**Which file format does the CIM use?**

The base model has no file format of its own. Network model exchanges commonly use CIMXML, an XML format based on the CIM RDF schema and defined in IEC 61970-552, with a profile such as IEC 61970-452 choosing what goes in the file.

**Can a product be certified against IEC 61970-301?**

Not against the base model on its own. What can be shown is that two tools exchange a named profile and edition correctly, which is why interoperability is tested exchange by exchange with real files.

## Official sources

Read the official text before relying on any detail. What applies to you depends on your role, your location and the version in force.

- [IEC 61970-301:2020+AMD1:2022 on the IEC webstore](https://webstore.iec.ch/en/publication/74467)
- [IEC 61970-301:2020 (Edition 7.0)](https://webstore.iec.ch/en/publication/62698)
- [IEC 61970-452:2021 (static network model profiles)](https://webstore.iec.ch/en/publication/64844)
- [IEC 61970-552:2016 (CIMXML model exchange format)](https://webstore.iec.ch/en/publication/25939)

These guides explain each standard in plain terms. They are not legal advice, and they do not state that any product or organization conforms to a standard.

## Planning software around this standard?

Tell us which systems are involved and what you need to show. We will help you build the requirements in from the start.

[Discuss your project](https://quantlix.com/en/contact/)