# IEC 61850: communication and data models for power utility automation

IEC 61850 is the international standard series for communication in power utility automation, defining device data models, the SCL configuration language and fast messaging for substations and other grid assets.

[Discuss your project](https://quantlix.com/en/contact/) [Read the key points](https://quantlix.com/en/standards/iec-61850/#standard-overview)

## At a glance

**Full name**

Communication networks and systems for power utility automation

**Published by**

International Electrotechnical Commission (IEC), Technical Committee 57

**Type**

International standard series, with related technical reports and specifications

**Current version**

Multi-part series; the IEC series bundle of 14 October 2026 lists 53 parts. Parts 7-2, 7-3, 7-4 and 8-1 are consolidated Edition 2.1 (2020); Part 6 is Edition 2.2 (2024)

**Applies to**

Utilities, system integrators and device makers engineering substations, protection and control, distributed energy resources and other utility automation

**Last reviewed**

November 16, 2026 (2026-11-16)

## In plain terms

### Key points

- It is a series, not a single protocol: data models, configuration, services and protocol mappings sit in separate parts.
- Logical nodes in Part 7-4 give each device function a standard name, so data means the same thing across vendors.
- SCL files from Part 6 carry device and substation configuration between engineering tools from different makers.
- GOOSE and sampled values carry time-critical data over Ethernet, while MMS serves client-server traffic over TCP/IP.
- Conformance tests in Part 10 check individual devices and tools; a working system still needs project-level testing.

### What is IEC 61850?

IEC 61850 is **an international standard series for communication in power utility automation**, published by the International Electrotechnical Commission. It started with substation automation and now reaches distributed energy resources, distribution automation, hydro plants and more. Rather than defining only a wire protocol, it describes what a device knows, how that knowledge is named, how a system is configured and how data moves.

The aim is interoperability between vendors. Substations used to mix proprietary protocols and point lists that had to be mapped by hand. With a shared data model and a shared configuration language, a protection relay from one maker and a gateway from another can understand each other with much less custom engineering.

### What the IEC 61850 series covers

- **Data models (Parts 7-3 and 7-4).** Functions are modeled as logical nodes, such as a circuit breaker (XCBR) or distance protection (PDIS), built from common data classes that carry values, quality and timestamps.
- **Abstract services (Part 7-2).** The abstract communication service interface defines what a client can ask of a server, such as reading, reporting, logging and control, plus a publisher-subscriber mechanism for fast events and sampled measurements.
- **Configuration language (Part 6).** The System Configuration description Language (SCL) is an XML format for exchanging device capabilities, substation layouts and communication settings between engineering tools.
- **Protocol mappings (Parts 8-1 and 9-2).** Part 8-1 maps the services to MMS (Manufacturing Message Specification) and directly to Ethernet frames for GOOSE, while Part 9-2 maps sampled values onto Ethernet.
- **Project and test parts (Parts 4 and 10).** Part 4 covers system and project management, and Part 10, amended in 2025, defines conformance tests for client, server and sampled value devices and for engineering tools.

### How it works: GOOSE, sampled values and MMS

IEC 61850 traffic falls into two groups. **Client-server exchanges run over MMS on TCP/IP**: a gateway or station computer reads values, receives reports and logs, and sends controls, with select-before-operate where the function needs it. This traffic tolerates ordinary network delays.

Time-critical traffic skips TCP/IP and goes straight onto Ethernet. GOOSE (Generic Object Oriented Substation Event) messages are multicast by a publishing device and retransmitted at increasing intervals after each change, so subscribing relays receive trips, blocking signals and interlocking states quickly and reliably. Sampled values stream digitized current and voltage measurements from merging units on the process bus, replacing much of the copper wiring to instrument transformers. Both depend on accurate time, which IEC/IEEE 61850-9-3 addresses with a precision time protocol profile for power utility automation.

### How it shows up in software projects

- **SCL as the source of truth.** Integration code reads the SCD file to discover devices, logical nodes and data sets instead of relying on a separate hand-made point list.
- **Quality and time with every value.** Each data attribute arrives with a quality descriptor and timestamp, and historians and analytics keep both rather than storing the bare value.
- **Gateways and mappings.** Enterprise and cloud systems usually reach substation data through a gateway that acts as an MMS client or translates to [DNP3](https://quantlix.com/en/standards/dnp3/) or [IEC 60870-5-104](https://quantlix.com/en/standards/iec-60870-5-104/), with every mapping documented.
- **Read-only by default.** Projects that analyze substation data leave protection and control in the station environment and read data without publishing on the station bus.
- **Edition awareness.** Devices built to different editions can differ in SCL schema and data models, so each interface records the editions and namespace versions it supports.

### How we work with IEC 61850

We build the software around the substation: tools that parse and check SCL files, data pipelines that bring IEC 61850 values with their quality and timestamps into historians and analytics, and integrations that link substation data to outage, asset and planning systems. We also help you design the security side with [IEC 62351](https://quantlix.com/en/standards/iec-62351/) in mind.

Protection engineering and the certification of devices stay with your engineers, the device makers and accredited test labs. Our part is making the data dependable once it leaves the bay. This work sits in our Utilities and Infrastructure practice, led by [Dr. Abdel-Hadi Hor](https://quantlix.com/en/about/leadership/abdel-hadi-hor/); see our [energy and utilities](https://quantlix.com/en/industries/energy-and-utilities/) and [IoT and edge computing](https://quantlix.com/en/services/iot-edge-computing/) pages for more.

## Where it applies

Industries where this standard often shapes the work.

- ### [Energy & Utilities](https://quantlix.com/en/industries/energy-and-utilities/)

  Renewable energy, smart grids and energy storage systems

## Related standards

[All standards](https://quantlix.com/en/standards/)

- IEC 62351

  ### [Security for power system protocols](https://quantlix.com/en/standards/iec-62351/)

  IEC 62351 is the IEC series that adds authentication, encryption, access control and key management to the communication protocols that run power systems, such as IEC 61850, IEC 60870-5 and DNP3.
- DNP3

  ### [SCADA protocol for field devices](https://quantlix.com/en/standards/dnp3/)

  DNP3 is the Distributed Network Protocol, standardized as IEEE 1815, that SCADA masters use to poll and control RTUs and IEDs in electric, water and other utilities, with event reporting and time-stamped data.
- IEC 60870-5-104

  ### [Telecontrol over TCP/IP networks](https://quantlix.com/en/standards/iec-60870-5-104/)

  IEC 60870-5-104 is the international telecontrol standard that carries IEC 60870-5-101 messages over TCP/IP, so control centers can monitor and control substations and other remote sites over IP networks.
- IEC 61970-301

  ### [The CIM base for power systems](https://quantlix.com/en/standards/iec-61970-301/)

  IEC 61970-301 is the international standard that defines the base of the Common Information Model (CIM), a shared description of power system equipment, connectivity and measurements used across grid software.

## Services that support this work

The services we usually bring to projects that involve this standard.

[View all services](https://quantlix.com/en/services/)

### [IoT and edge computing](https://quantlix.com/en/services/iot-edge-computing/)

Connect machines, sensors and business software with assessed IoT and edge integrations. Define data meaning, connectivity, permitted actions and recovery.

### [Enterprise applications](https://quantlix.com/en/services/enterprise-applications/)

Quantlix designs and builds enterprise applications for internal workflows, business rules and system integration, with clear access controls and maintainable architecture.

### [Data analytics](https://quantlix.com/en/services/data-analytics/)

Quantlix builds analytics pipelines and business intelligence tools that turn operational data into defined metrics, useful reports and decision support.

## Questions, answered

What teams usually ask us about this standard.

**Is IEC 61850 a protocol?**

It is more than one. IEC 61850 defines an abstract data model and services, then maps them onto concrete protocols: MMS for client-server communication, GOOSE for fast events and sampled values for streamed measurements. IEC itself describes the series as much more than a communication protocol.

**What is the latest version of IEC 61850?**

There is no single version. Each part has its own edition: Parts 7-2, 7-3, 7-4 and 8-1 are consolidated Edition 2.1 from 2020, Part 6 reached Edition 2.2 in November 2024 and Part 10 reached Edition 2.1 in July 2025. Record the edition of every part your project depends on.

**What is the difference between GOOSE and MMS?**

MMS carries client-server exchanges such as reading values, reports, logs and controls between a gateway and devices. GOOSE is a publish-subscribe message sent directly over Ethernet for time-critical signals such as trips and interlocking between devices.

**What are ICD, SCD and CID files?**

They are SCL file types defined in IEC 61850-6. An ICD file describes what a device type can do, an SCD file describes the configured substation with all its devices and communication, and a CID file holds the configuration loaded into one device.

**How is IEC 61850 secured?**

Through the IEC 62351 series. IEC 62351-6 (2020) covers security for IEC 61850, and IEC 62351-4 covers profiles that include MMS. Which measures apply depends on the message type and the network design.

**Is IEC 61850 only for substations?**

No. It began with substation automation and now also covers distributed energy resources, distribution automation, hydro plants and more, for example through Parts 7-420 and 7-410.

## Official sources

Read the official text before relying on any detail. What applies to you depends on your role, your location and the version in force.

- [IEC 61850 series on the IEC webstore](https://webstore.iec.ch/en/publication/6028)
- [What is IEC 61850 (IEC)](https://iec61850.dvl.iec.ch/what-is-61850/)
- [IEC 61850-6:2009+AMD1:2018+AMD2:2024 (SCL)](https://webstore.iec.ch/en/publication/103863)
- [IEC 61850-8-1:2011+AMD1:2020 (MMS and Ethernet mapping)](https://webstore.iec.ch/en/publication/66585)

These guides explain each standard in plain terms. They are not legal advice, and they do not state that any product or organization conforms to a standard.

## Planning software around this standard?

Tell us which systems are involved and what you need to show. We will help you build the requirements in from the start.

[Discuss your project](https://quantlix.com/en/contact/)