---
title: "Software and AI for energy and utilities | Quantlix"
description: "Software and AI for utilities: GIS, asset and outage integration, asset risk, predictive maintenance and grid analytics, led by 23+ years of utility experience."
canonical: "https://quantlix.com/en/industries/energy-and-utilities/"
last-updated: 2026-11-16
---

Source: https://quantlix.com/en/industries/energy-and-utilities/
Language: en
Description: Software and AI for utilities: GIS, asset and outage integration, asset risk, predictive maintenance and grid analytics, led by 23+ years of utility experience.

# Software and AI for energy and utilities

We help utilities and energy companies connect their GIS, asset, outage and grid systems into one clear view, then use AI to anticipate problems, plan maintenance and support faster restoration.

[Discuss your project](https://quantlix.com/en/contact/) [See how we can help](https://quantlix.com/en/industries/energy-and-utilities/#industry-use-cases)

![A steel high-voltage transmission tower carries power lines across a dusk sky with blue and pink clouds.](https://quantlix.com/_astro/energy-utilities.BGWqg96F_1Bvnt5.webp)

[All industries](https://quantlix.com/en/industries/)

## Technology that fits the way you work.

### How software and AI help utilities and energy companies

Software and AI help utilities **see their whole network clearly and act before problems reach customers**. When GIS, asset management, outage and grid systems share accurate data, crews find faults faster, planners invest where risk is highest and AI can support decisions with information people trust.

Utility systems are often built and run separately, by different teams and on different upgrade cycles. Connecting them into one digital environment is where the biggest improvements come from, and it is the foundation for using AI well.

### The systems we connect

This is the sector we know best. Our Utilities and Infrastructure practice is led by [Dr. Abdel-Hadi Hor](https://quantlix.com/en/about/leadership/abdel-hadi-hor/), who has spent more than 23 years designing and connecting GIS, asset, outage and distribution management systems. Over his career, he has contributed to modernization programs at North American utilities including Oncor, AEP, National Grid and LADWP. The systems the practice works with most are:

- **Enterprise GIS**, such as Esri Utility Network and Hexagon HxGN NetWorks, which maps the network, its assets and how they connect. An accurate connectivity model is what outage, planning and field tools all rely on.
- **Enterprise asset management (EAM)**, such as IBM Maximo, which tracks equipment, inspections and maintenance work. Linked to GIS, it gives every pole, pipe and transformer one record, location and history.
- **Outage management (OMS) and advanced distribution management systems (ADMS)**, which help crews find faults and restore service and help operators monitor and switch the grid. Both work best when the network model they receive from GIS is current.
- **SCADA**, the supervisory control and data acquisition systems that gather live readings from substations and field devices. Read through protected paths, that data adds real-time context to planning and analytics.
- **Meter data management (MDMS)** and advanced metering, which hold interval readings and meter events. Connected to outage and planning tools, meter signals help confirm outages and restorations and show how load is changing.
- **Distributed energy resource management (DERMS)**, which monitors and coordinates rooftop solar, batteries, EV charging and flexible demand. Linked to ADMS and planning, it helps the network take on more local generation.

On top of these sit geospatial analytics and digital twins, which show how the network behaves over time and let planners test a change before crews go out.

### Standards that shape the work

Utility integration goes better when every system agrees on what a transformer, a feeder or a meter is. The **Common Information Model (CIM)** provides that shared meaning: [IEC 61970-301](https://quantlix.com/en/standards/iec-61970-301/) defines the base model for power networks and [IEC 61968-11](https://quantlix.com/en/standards/iec-61968-11/) extends it for distribution assets, customers, metering and work. Designing interfaces around the CIM means each new connection maps to one agreed model instead of to every other system.

Operational data has its own protocols. [IEC 61850](https://quantlix.com/en/standards/iec-61850/) describes communication inside substations, [DNP3](https://quantlix.com/en/standards/dnp3/) and [IEC 60870-5-104](https://quantlix.com/en/standards/iec-60870-5-104/) carry telecontrol data between field devices and control centers, and [IEEE 2030.5](https://quantlix.com/en/standards/ieee-2030-5/) and [OpenADR](https://quantlix.com/en/standards/openadr/) connect distributed energy and demand response programs. Security shapes all of it. In North America, [NERC CIP](https://quantlix.com/en/standards/nerc-cip/) sets cybersecurity requirements for the systems that support the bulk power grid, and [IEC 62351](https://quantlix.com/en/standards/iec-62351/) adds security to the power system protocols themselves. [IEEE 1366](https://quantlix.com/en/standards/ieee-1366/) reliability indices, such as SAIDI and SAIFI (the average outage duration and frequency per customer), then show whether the work is reaching customers.

### An example from a storm

*Illustrative example:* a storm brings down lines across several feeders. Customer calls, the “last gasp” messages smart meters send as they lose power and the connected network model combine to suggest the most likely fault locations. Dispatchers prioritize crews by the number of customers affected, and field teams see the right assets, switching notes and access details on their tablets. As each section is restored, meter readings confirm that power is back before the outage is closed, and the event record later feeds the reliability report.

### Security, data and oversight

Grid systems carry real consequences, so **operational technology stays protected**. We work within your control environment’s separation and access rules, prefer read-only and one-way data paths from SCADA and ADMS and keep customer and meter data limited to the people and purposes that need it, with every access logged. Where NERC CIP or similar rules apply, your compliance team sets the boundaries and we design inside them. AI stays advisory: models suggest fault locations, restoration times or asset risk scores with the evidence behind them, and operators and engineers make every switching and investment decision.

### What to look for in a technology partner

- **Domain depth.** People who have worked inside utility GIS, asset, outage and distribution programs and know how those systems fit together.
- **Model discipline.** Integration designed around the CIM, with every mapping documented so your own team can maintain it.
- **Data quality first.** A plan to reconcile GIS, asset and field records before analytics or AI depend on them.
- **Respect for operations.** Changes that follow your switching, security and outage procedures and steer clear of storm season and peak load.
- **Work with what you own.** Connections to the GIS, EAM, OMS and metering products you already run, rather than a push to replace them.

### What to bring to the first conversation

Start with the data your teams question most, such as asset records that do not match the field or outage maps that lag behind events. Bring a rough picture of your GIS, asset, outage and metering systems and the decision you would like to make better. We will assess the systems involved and suggest a practical first step, often a focused piece of [enterprise application](https://quantlix.com/en/services/enterprise-applications/) integration. [Tell us where you would like to start](https://quantlix.com/en/contact/).

### Who leads this work

[Dr. Abdel-Hadi Hor](https://quantlix.com/en/about/leadership/abdel-hadi-hor/)
President, Utilities & Infrastructure, and Chief Strategy Officer

Dr. Hor leads Utilities & Infrastructure at Quantlix and helps shape its global strategy. An enterprise architect and geospatial engineer, he has spent more than 23 years building the systems utilities depend on every day.

## Where we can help

Projects we can shape and build with your team.

### GIS and asset integration

Connect enterprise GIS with asset management, so every pole, pipe and transformer has one accurate record, location and history.

### Outage and restoration support

Bring outage, network and customer data together to help crews find faults and restore service sooner.

### Asset risk and predictive maintenance

Combine condition, age and inspection data to rank assets by risk and plan investment where it matters most.

### Grid and demand analytics

Forecast load, plan for renewables and storage and give planners a clearer picture of how the network behaves.

### Distributed energy and demand response

Bring rooftop solar, batteries, EV charging and flexible demand into planning and operations, using protocols such as IEEE 2030.5 and OpenADR.

### Field mobility and work management

Give crews maps, asset history and work orders on tablets that work offline, so field updates flow back to GIS and asset records without retyping.

## Standards we work with

The standards, protocols and regulations that most often shape software in this industry. Each guide explains one in plain terms.

[All standards](https://quantlix.com/en/standards/)

- IEC 61968-11

  ### [CIM extensions for distribution](https://quantlix.com/en/standards/iec-61968-11/)

  IEC 61968-11 is the international standard that extends the Common Information Model (CIM) to electricity distribution, so GIS, asset, outage and metering systems can describe the same network in the same way.
- IEC 61970-301

  ### [The CIM base for power systems](https://quantlix.com/en/standards/iec-61970-301/)

  IEC 61970-301 is the international standard that defines the base of the Common Information Model (CIM), a shared description of power system equipment, connectivity and measurements used across grid software.
- NERC CIP

  ### [Cyber security for the bulk power system](https://quantlix.com/en/standards/nerc-cip/)

  NERC CIP is the family of mandatory reliability standards that protect the cyber systems and critical facilities of the North American bulk power system, from system categorization to supply chain risk.
- IEC 61850

  ### [Power utility automation and substations](https://quantlix.com/en/standards/iec-61850/)

  IEC 61850 is the international standard series for communication in power utility automation, defining device data models, the SCL configuration language and fast messaging for substations and other grid assets.
- DNP3

  ### [SCADA protocol for field devices](https://quantlix.com/en/standards/dnp3/)

  DNP3 is the Distributed Network Protocol, standardized as IEEE 1815, that SCADA masters use to poll and control RTUs and IEDs in electric, water and other utilities, with event reporting and time-stamped data.
- IEC 60870-5-104

  ### [Telecontrol over TCP/IP networks](https://quantlix.com/en/standards/iec-60870-5-104/)

  IEC 60870-5-104 is the international telecontrol standard that carries IEC 60870-5-101 messages over TCP/IP, so control centers can monitor and control substations and other remote sites over IP networks.
- IEEE 2030.5

  ### [Smart Energy Profile for DER](https://quantlix.com/en/standards/ieee-2030-5/)

  IEEE 2030.5 is the IEEE application protocol, also known as Smart Energy Profile 2.0, that lets utilities exchange schedules, controls and data with inverters, storage, EV chargers and other energy devices over IP networks.
- OpenADR

  ### [Automated demand response signals](https://quantlix.com/en/standards/openadr/)

  OpenADR is the Open Automated Demand Response standard from the OpenADR Alliance, used by utilities and aggregators to send demand response, price and grid signals to customer systems and receive reports back.
- Green Button

  ### [Customer energy usage data sharing](https://quantlix.com/en/standards/green-button/)

  Green Button is the North American initiative, built on the NAESB REQ.21 ESPI standard, that lets utility customers download their energy usage data or authorize apps to receive it directly.
- IEEE 1366

  ### [Distribution reliability indices](https://quantlix.com/en/standards/ieee-1366/)

  IEEE 1366 is the IEEE guide that defines distribution reliability indices such as SAIDI, SAIFI, CAIDI and MAIFI, and the major event day method utilities use to separate extreme days from normal performance.
- ISO 55001

  ### [Asset management system requirements](https://quantlix.com/en/standards/iso-55001/)

  ISO 55001 is the international standard that sets requirements for an organization's asset management system, so decisions about assets deliver value across their whole life.
- IEC 62351

  ### [Security for power system protocols](https://quantlix.com/en/standards/iec-62351/)

  IEC 62351 is the IEC series that adds authentication, encryption, access control and key management to the communication protocols that run power systems, such as IEC 61850, IEC 60870-5 and DNP3.
- IEC 62443

  ### [Industrial control system security](https://quantlix.com/en/standards/iec-62443/)

  IEC 62443 is the international series of standards for securing industrial automation and control systems, with requirements for asset owners, service providers, system integrators and product suppliers.

## One view of the network

GIS, asset management, outage and grid systems share data through a common model, so field crews, control rooms and planners see the same network.

1. Field crews and sensors
2. GIS and asset management
3. Outage and grid systems
4. Planning and control room teams

## Services behind this work

Each project draws on a few core services. These are the ones that fit best.

[View all services](https://quantlix.com/en/services/)

### [Enterprise applications](https://quantlix.com/en/services/enterprise-applications/)

Quantlix designs and builds enterprise applications for internal workflows, business rules and system integration, with clear access controls and maintainable architecture.

### [Data analytics](https://quantlix.com/en/services/data-analytics/)

Quantlix builds analytics pipelines and business intelligence tools that turn operational data into defined metrics, useful reports and decision support.

### [Artificial intelligence](https://quantlix.com/en/services/artificial-intelligence/)

Industrial AI for inspection, maintenance and operational decision support. Quantlix scopes data, integration, evaluation and human review around one workflow.

## Questions, answered

What teams in this industry usually ask us first.

**Do you have experience with utility systems?**

Yes. Our Utilities and Infrastructure practice is led by Dr. Abdel-Hadi Hor, who has spent more than 23 years designing and connecting GIS, asset, outage and distribution management systems. Over his career, he has contributed to modernization programs at North American utilities including Oncor, AEP, National Grid and LADWP.

**Can you connect our GIS with our asset management system?**

Yes. Connecting enterprise GIS, such as Esri Utility Network or Hexagon, with asset management systems, such as IBM Maximo, is one of the core areas of experience in this practice.

**Which standards do you work with in utility projects?**

The ones your systems and regulators already use. Integration is designed around the Common Information Model (IEC 61970-301 and IEC 61968-11). Substation and field data use IEC 61850, DNP3 and IEC 60870-5-104, distributed energy and demand response use IEEE 2030.5 and OpenADR, and customer energy data uses Green Button. Security work follows NERC CIP, IEC 62351 and IEC 62443 where they apply, reliability is reported with IEEE 1366 indices and ISO 55001 frames asset management.

**Can AI help during outages?**

Yes, as decision support. AI can help suggest likely fault locations, estimate restoration times and prioritize crews, while operators stay in control of every switching decision.

**How do you approach security for grid systems?**

Operational systems stay protected. We follow the separation and access rules your control environment requires and align with the security standards that apply to you, such as NERC CIP in North America.

**Where should a utility start?**

Often with data quality: a clean, connected model of the network and its assets. Once GIS, asset and outage records agree, predictive maintenance and analytics become far more reliable.

## Related industries

Sectors that share many of the same standards and systems.

[All industries](https://quantlix.com/en/industries/)

- ### [Manufacturing](https://quantlix.com/en/industries/manufacturing/)

  Connected factories, quality inspection and production planning
- ### [Construction](https://quantlix.com/en/industries/construction/)

  Project planning, site operations and connected building systems
- ### [Oil & Gas](https://quantlix.com/en/industries/oil-and-gas/)

  Asset monitoring, field data and maintenance planning

## Tell us how your work runs today.

Share your goals, your systems and what is getting in the way. We will suggest a practical first step together.

[Discuss your project](https://quantlix.com/en/contact/)
